KUS series ultrasonic transmitter
Unit in the diagram is mm.
600B series
     transmitter dimensions
    
   
      
   
      
    

| Cable color | Pin | description | Note | 
| Red | 1 | Power supply |  | 
| Black | 2 | GND |  | 
|  | 3 | Analogue output  | The 600A will work in mode 1 or 0 cannot work in power save mode, if
  the 4-20mA , 0-3.3V 0-5V analogue output  used..  | 
|  | 4 | RS485A+ |  | 
|  | 5 | RS485B- |  | 
General specifications
| 600A | |
| Sensing
  range | 300... 3000
  mm. the measure distance can reach 6 meters if the power supply reach to 12V. | 
| Adjustment range | 300….3000mm | 
| Unusable area | 0 ... 300 mm | 
| Standard
  target plate | 100 mm x 100 mm | 
| Transducer frequency | approx.220
  kHz | 
| Response delay | approx. 10 ms | 
Electrical specifications
| Operating
  voltage UB | 3.3 ... 24 V DC , ripple
  10 %SS  | 
| No-load supply current I0 | ≤ 20 mA active period  ≤0.3mA during sleep time | 
The detail refer to the 600A software engineer application guide.
If the sensor is installed at the environment temperature fall
below 0℃,It should
do well on the protective
measures. In case of
direct mounting of
the sensor in a through hole using the
steel
nuts, it has to
be fixed at the
middle
of the housing thread.
|  GXUS | Body size | OUTPUT | Max range | Description | |
|  | 600A |  | |||
| Customized | Customized | ||||
|  | 4-20mA | 4-20mA mode
  output with RS485 MODBUS protocol | |||
| 0-3.0V | The power supply
  range is 3.3 at least | ||||
| 0-5.0V | The power
  supply range is 5.0 at least | ||||
| RS485 | Power save
  mode with RS485 MODBUS protocol | ||||
|  |  | XXX mm | Xxx mm is the maxim range can be detected | ||
| GXUS | 600A | RS485 | 3000mm |  | |